Mouse Cytokine Array / Chemokine Array 44-Plex (MD44)

We Will Test Your Sample(s) and Provide Results For The Following Biomarkers:

Eotaxin, Erythropoietin, 6Ckine, Fractalkine, G-CSF, GM-CSF, IFNB1, IFNγ, IL-1α, IL-1β, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-9, IL-10, IL-11, IL-12 (p40), IL-12 (p70), IL-13, IL-15, IL-16, IL-17, IL-20, IP-10, KC, LIF, LIX, MCP-1, MCP-5, M-CSF, MDC, MIG, MIP-1α, MIP-1β, MIP-2, MIP-3α, MIP-3B, RANTES, TARC, TIMP-1, TNFα, and VEGF. (LIX results also included but not validated)

Discovery Price $56.90/sample (single analysis / includes sample filtration)

Single analysis volume required: 75uL Duplicate analysis volume required: 125uL Recommended Dilution: *Dilutions: Serum and Plasma are recommended to be run at a 2-fold dilution. If you wish to run your samples at a dilution, predilute your samples with PBS pH~7.5. For example, add 37.5ul of serum to 37.5ul of PBS for single analysis volume of 75ul. Indicate your dilution factor on the order form.      ****** If you expect your samples to have low cytokine levels, inquire about a High Sensitivity panel.   

Please Click for information on Shipping, Tubes, Volumes, Dilution and Labeling for Discovery Assays

Human
Mouse
Rat
Porcine
Non Human Primate
Canine
Feline
Horse
BAL Fluid
Cell Lysate
CSF
Plasma-Citrate
Plasma-EDTA
Plasma-Heparin
Serum
Synovial Fluid
Tissue Homogenate
Tissue/Cell Culture
Urine
Other
No Additional Sample Type
BAL Fluid
Cell Lysate
CSF
Plasma-Citrate
Plasma-EDTA
Plasma-Heparin
Serum
Synovial Fluid
Tissue Homogenate
Tissue/Cell Culture
Urine
Other
No Tertiary Sample Type
BAL Fluid
Cell Lysate
CSF
Plasma-Citrate
Plasma-EDTA
Plasma-Heparin
Serum
Synovial Fluid
Tissue Homogenate
Tissue/Cell Culture
Urine
Other
No
Yes, 2 Fold

(1 Part Sample and 1 Part Diluent)

Yes, Other

Please Specify in the "Special Requests" Notes at Checkout

0.5-0.65mL Snap Cap

(Discovery Assay Compatible)

1.5mL Snap Cap

(Non Compatible Tubes $3.00/ Tube)

96-Well Plate

(Non Compatible Tubes $3.00/ Tube)

Cryo Screw Top Tube

(Non Compatible Tubes $3.00/ Tube)

Other

(Non Compatible Tubes $3.00/ Tube)

Alpha-Numerically

(ie. S1,S2,S3)

Other

Please send Sample list (excel)

No
Yes

(Category A)

Yes

(Category B)

Clear all selections
Clear
If you selected "Yes" Please state the infectious nature of your sample.
How to classify Biological Samples
Please Enter The Volume of Samples You Will Be Sending
SKU: MD44 Category: Tag:

Description

Biomarker Analytes: Eotaxin, Erythropoietin, 6Ckine, Fractalkine, G-CSF, GM-CSF, IFNB1, IFNγ, IL-1α, IL-1β, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-9, IL-10, IL-11, IL-12 (p40), IL-12 (p70), IL-13, IL-15, IL-16, IL-17, IL-20, IP-10, KC, LIF, LIX, MCP-1, MCP-5, M-CSF, MDC, MIG, MIP-1α, MIP-1β, MIP-2, MIP-3α, MIP-3B, RANTES, TARC, TIMP-1, TNFα, and VEGF

Price:$56.90/ sample (single analysis)

Volume Required:

75μl single analysis. 125μl duplicate analysis. 175μl triplicate analysis.
Biomarker Research Areas: Immune response, inflammatory disease, allergy, irritable bowel disease (IBD), sepsis and cancer.

Multiplex Assay Overview:

The assay service provided by Eve Technologies on their Mouse Cytokine Array / Chemokine Array 44-Plex facilitates research on immune response, inflammatory disease, allergy, irritable bowel disease (IBD), sepsis and cancer. This Discovery Assay® measures thirty-two biomarkers simultaneously in a single microwell. The assay is designed for extracellular protein analysis in nearly all types of biological samples.

Background Information:

“Cytokine” is a general term used for a diverse group of soluble proteins and peptides which act as regulators under both normal and pathological conditions to modulate the functional activities of individual cells and tissues. These proteins also mediate direct interactions between cells and regulate processes taking place in the extracellular environment. Cytokines differ from hormones in that they act on a wider spectrum of target cells. Responses to cytokines result in inflammation where the immune system attempts to eradicate foreign antigens and begin the healing process. Consequently, the inflammatory process plays a key protective role in immunity.

Also, unlike hormones, they are not produced by specialized cells which are organized in specialized glands. The cytokine group of proteins includes lymphokines, interferons, colony stimulating factors and chemokines. Cytokine and chemokine research plays a significant role in achieving a deeper understanding of the immune system and its multi-faceted response to most antigens, as well as disease states such as inflammatory disease, allergic reactions, irritable bowel disease (IBD), sepsis, and cancer.
Intended Sample Type: Mouse serum or plasma (EDTA recommended), cell cultures, tissue homogenates and others. Due to a wide range of sample conditions, a pilot run is recommended for cell cultures, tissue homogenates, and other sample types not listed.

Special Sample Preparation:

Serum and Plasma are recommended to be run at a 2-fold dilution. If you wish to run your samples at a dilution, predilute your samples with PBS
pH~7.5.
ALL samples must be centrifuged prior to aliquoting. The aliquot should be drawn from the middle of the sample volume. Samples that have a high amount of contaminants, cellular debris, lipids, or coagulation can result in a volume loss as volume is being displaced by this debris and they can clog the filters. Highly turbid or coagulated samples that clog the filters will be partially filtered by piercing the clogged membrane

Usage Statement:

Unless otherwise stated our products and services are intended for research use only.

Detection Method:

Multiplex Immunoassay analyzed with a BioPlex 200 Mouse Cytokine Array/ Chemokine Array 32-Plex and 13-plex

Assay Kit Source:

Millipore MILLIPLEX

Sensitivity, Variation, & Accuracy

Sensitivity Intra-assay Inter-assay Accuracy
Biomarkers pg/mL %CV %CV % Recovery
Eotaxin 0.4 2.1 4.4 98.1
Erythropoietin 8 less than 20 less than 10 96
Exodus 2 4 less than 20 less than 10 98
Fractalkine 8 less than 20 less than 10 106
G-CSF 0.5 2.6 5.1 91.6
GM-CSF 10.9 2.0 6.4 91.8
IFNβ-1 10 less than 20 less than 10 102
IFNγ 0.4 1.9 4.9 95.3
IL-1α 10.3 4.4 4.7 92.1
IL-1β 5.4 2.5 5.8 99.3
IL-2 0.6 1.5 3.8 91.2
IL-3 0.7 1.7 7.2 96.6
IL-4 0.2 1.7 5.1 95.0
IL-5 0.3 2.5 6.3 90.4
IL-6 0.4 2.3 5.4 92.2
IL-7 1.4 2.3 4.6 98.9
IL-9 17.3 2.7 4.9 101.6
IL-10 1.2 1.4 5.1 91.0
IL-11 10 less than 20 less than 10 98
IL-12 (p40) 3.9 1.6 6.6 89.7
IL-12 (p70) 4.8 2.6 4.1 84.9
IL-13 33.3 2.5 ≤15 106.5
IL-15 7.4 2.2 7.2 89.5
IL-16 1 less than 20 less than 10 92
IL-17A 0.2 2.0 5.8 96.7
IL-20 21 less than 20 less than 10 94
IP-10 0.1 2.2 3.4 94.8
KC 1.8 3.3 6.0 93.3
LIF 0.5 3.3 2.9 97.2
LIX 22.1 2.5 8.3 93.1
MCP-1 6.7 1.9 4.3 95.0
MCP-5 1 less than 20 less than 10 95
M-CSF 3.5 2.7 5.7 89.5
MDC 2 less than 20 less than 10 92
MIG 2.4 3.2 4.7 92.5
MIP-1α 7.7 1.5 5.5 96.7
MIP-1β 11.9 1.9 4.6 96.4
MIP-2 30.6 2.9 6.8 90.5
MIP-3α 5 less than 20 less than 10 90
MIP-3β 8 less than 20 less than 10 100
RANTES 2.7 4.9 12.4 95.0
TARC 2 less than 20 less than 10 93
MDC 2 less than 20 less than 10 92
TIMP-1 2 less than 20 less than 10 103
TNFα 1.7 2.6 9.3 94.0
VEGF 0.1 2.4 3.9 101.0

*Note: %CV is an appropriate measure of quality only for sample that have significant detectable concentrations for a particular analyte. Low concentration / low signal samples can often have a much higher %CV as the signals are at the limitations of the assay and fall within a flat portion of the curve.

% recovery is comparing the observed concentration to the expected concentration of samples spiked with the standard curve cocktail at various concentrations.

Reviews

There are no reviews yet.

Be the first to review “Mouse Cytokine Array / Chemokine Array 44-Plex (MD44)”

Got something to discuss?


Customer
luba.perry
8 months 1 day ago

Hello,

Can the mouse cytokine array and the mouse angiogenesis array be run from the same sample?
Thanks! Can a 1:3 dilution also be good for this array?

 
Resources
Please See our Documentation related to Sample Dilution, Shipping of Biological Samples, and other related information.
Resources
Please See our Documentation related to Sample Dilution, Shipping of Biological Samples, and other related information.
JOIN OUR COMMUNITY
Just one step to success!