Search

NEW – Early Access: Human MSD® Discovery Assay® Neurodegeneration 7-Plex Array (MSDND7)

NEW – Early Access
Ultrasensitive assay that simultaneously measures 7 key biomarkers spanning Alzheimer’s disease, Parkinson’s disease and other neurodegenerative disorders

GFAP |  NfL | pTau217 | Aβ40 | Aβ42 | LRRK2 | TDP-43 

Price
$169.97/sample
(single analysis)

 

Sample Volume Requirements
Single analysis 50 μL
Duplicate analysis 75 μL

TO ORDER THIS ASSAY - DESIGN YOUR RESEARCH PROJECT BELOW

Species Type
Sample Type & Qty
Sample Tube Type
Pilot Analysis
Infectious Nature
Review

ERROR: Please Select A Species Type.

Species Type

Next

Sample Type & Qty

BAL Fluid

Number of Samples

Volume (uL)

Dilution Factor
This refers to the dilution factor of the samples that you are sending. Note that some assays recommend a dilution factor for assay performance or to reduce the demand on precious sample volume. For example, a number of rat and mouse cytokine arrays recommend a 2-fold dilution for serum/plasma samples (1 part sample and 1 part diluent) - please contact us for more information if needed.

Cell Lysate

Number of Samples

Volume (uL)

Dilution Factor
This refers to the dilution factor of the samples that you are sending. Note that some assays recommend a dilution factor for assay performance or to reduce the demand on precious sample volume. For example, a number of rat and mouse cytokine arrays recommend a 2-fold dilution for serum/plasma samples (1 part sample and 1 part diluent) - please contact us for more information if needed.

CSF

Number of Samples

Volume (uL)

Dilution Factor
This refers to the dilution factor of the samples that you are sending. Note that some assays recommend a dilution factor for assay performance or to reduce the demand on precious sample volume. For example, a number of rat and mouse cytokine arrays recommend a 2-fold dilution for serum/plasma samples (1 part sample and 1 part diluent) - please contact us for more information if needed.

Plasma-Citrate

Number of Samples

Volume (uL)

Dilution Factor
This refers to the dilution factor of the samples that you are sending. Note that some assays recommend a dilution factor for assay performance or to reduce the demand on precious sample volume. For example, a number of rat and mouse cytokine arrays recommend a 2-fold dilution for serum/plasma samples (1 part sample and 1 part diluent) - please contact us for more information if needed.

Plasma-EDTA

Number of Samples

Volume (uL)

Dilution Factor
This refers to the dilution factor of the samples that you are sending. Note that some assays recommend a dilution factor for assay performance or to reduce the demand on precious sample volume. For example, a number of rat and mouse cytokine arrays recommend a 2-fold dilution for serum/plasma samples (1 part sample and 1 part diluent) - please contact us for more information if needed.

Plasma-Heparin

Number of Samples

Volume (uL)

Dilution Factor
This refers to the dilution factor of the samples that you are sending. Note that some assays recommend a dilution factor for assay performance or to reduce the demand on precious sample volume. For example, a number of rat and mouse cytokine arrays recommend a 2-fold dilution for serum/plasma samples (1 part sample and 1 part diluent) - please contact us for more information if needed.

Serum

Number of Samples

Volume (uL)

Dilution Factor
This refers to the dilution factor of the samples that you are sending. Note that some assays recommend a dilution factor for assay performance or to reduce the demand on precious sample volume. For example, a number of rat and mouse cytokine arrays recommend a 2-fold dilution for serum/plasma samples (1 part sample and 1 part diluent) - please contact us for more information if needed.

Synovial Fluid

Number of Samples

Volume (uL)

Dilution Factor
This refers to the dilution factor of the samples that you are sending. Note that some assays recommend a dilution factor for assay performance or to reduce the demand on precious sample volume. For example, a number of rat and mouse cytokine arrays recommend a 2-fold dilution for serum/plasma samples (1 part sample and 1 part diluent) - please contact us for more information if needed.

Tissue Homogenate

Number of Samples

Volume (uL)

Dilution Factor
This refers to the dilution factor of the samples that you are sending. Note that some assays recommend a dilution factor for assay performance or to reduce the demand on precious sample volume. For example, a number of rat and mouse cytokine arrays recommend a 2-fold dilution for serum/plasma samples (1 part sample and 1 part diluent) - please contact us for more information if needed.

Tissue/Cell Culture Supernatant

Number of Samples

Volume (uL)

Dilution Factor
This refers to the dilution factor of the samples that you are sending. Note that some assays recommend a dilution factor for assay performance or to reduce the demand on precious sample volume. For example, a number of rat and mouse cytokine arrays recommend a 2-fold dilution for serum/plasma samples (1 part sample and 1 part diluent) - please contact us for more information if needed.

Urine

Number of Samples

Volume (uL)

Dilution Factor
This refers to the dilution factor of the samples that you are sending. Note that some assays recommend a dilution factor for assay performance or to reduce the demand on precious sample volume. For example, a number of rat and mouse cytokine arrays recommend a 2-fold dilution for serum/plasma samples (1 part sample and 1 part diluent) - please contact us for more information if needed.

Other

Sample

Number of Samples

Volume (uL)

Dilution Factor
This refers to the dilution factor of the samples that you are sending. Note that some assays recommend a dilution factor for assay performance or to reduce the demand on precious sample volume. For example, a number of rat and mouse cytokine arrays recommend a 2-fold dilution for serum/plasma samples (1 part sample and 1 part diluent) - please contact us for more information if needed.

Next
Previous

Sample Tube Type
Conforming tubes are 0.5-0.65mL snap cap tubes. Having a conforming tube helps us complete your analysis efficiently and accurately. A $4.00 charge per sample tube may be added to your order if sample tubes are non-conforming.

0.5-0.65ml Snap Cap

Other Tube Type (Fee applies)

Label Type
Conforming tube labeling is with a constant letter from your last name followed by consecutive numbers. (ie. Last name Smith: S1, S2, S3, etc.). Labelling tubes in this manner helps us complete your analysis efficiently and accurately. A $4.00 charge per sample tube may be added to your order if sample labelling is non-conforming.

1 letter and consecutive numbers (multiple letters and missing numbers are non-conforming)

Other Label Type (Attach sample list at checkout, fee applies)

Next
Previous

Pilot Analysis

Pilot runs are recommended for medium to large cohorts of samples that lack homogeneity (i.e. n>20 of tissue homogenate samples, cell culture samples, or less common sample types which can have higher sources of variability and/or unpredictable analyte levels). Running a pilot in such instances will ensure an optimal dilution factor is used before running your entire sample cohort. Pilot runs are ideally done on samples that reflect the expected experimental range and are provided as separate aliquots/separate samples designated for the pilot run.

None

Yes - I will include additional pilot samples (RECOMMENDED: to remove consideration for inter-assay variables between pilot and main sample cohort assay sessions.) We typically recommend 2, one sample with a low expected analyte concentration and one with a high, to encompass the range of the standard curve.

Yes – I will indicate pilot samples from within my cohort (CAUTION: pilot samples will not be run again with the main assay. Inter-assay variables may result in a batch effect. We typically recommend 2, one sample with a low expected analyte concentration and one with a high, to encompass the range of the standard curve.

Next
Previous

Infectious Nature
If your samples are of an infectious nature, please contact us PRIOR TO SHIPPING. Please DO NOT SHIP infectious samples unless you have contacted us for requirements.

No

Yes (please state the infectious nature for reivew prior to shipping)

Review
Previous

Review

Species:

Samples:

Tube Type:

Pilot Analysis:

Pilot Sample Numbers:

Infectious Nature:

Total Number of Samples:

**Select the Replication in Which You Want Your Samples Tested:

Add To Cart
Add To Cart
Previous

Description

This assay uses the Meso Scale Discovery® (MSD®) platform.

Eve Technologies is pleased to offer early access to a new Neurodegeneration 7-Plex Discovery Assay on the MSD® platform, providing simultaneous measurement of key biomarkers spanning Alzheimer’s disease, Parkinson’s disease and other neurodegenerative disorders.
GFAP | NfL | pTau217 | Aβ40 | Aβ42 | LRRK2 | TDP-43
This novel multiplex panel brings together biomarkers representing complementary aspects of neurodegenerative disease biology, including amyloid and tau pathology, astrocytic activation, neuroaxonal injury and neurodegenerative proteinopathies.
GFAP and NfL are widely studied markers of astrocytic activation and neuroaxonal injury, while pTau217 and Aβ40/Aβ42 provide important measures associated with Alzheimer’s disease pathology. LRRK2 (leucine-rich repeat kinase 2) extends the panel into Parkinson’s disease and related lysosomal and cellular signaling pathways.
Notably, TDP-43 is newly available as a biomarker on the MSD® platform, expanding multiplex capabilities for the study of TDP-43 proteinopathies, including ALS, frontotemporal dementia and LATE.
By combining these seven biomarkers in a single MSD® assay, the Neurodegeneration 7-Plex Array provides a streamlined approach for translational neuroscience, biomarker discovery, longitudinal studies and research investigating overlapping or mixed neurodegenerative pathology.
NEW – Early Access
$169.97/sample – single analysis
For Research Use Only.
 
|